◆★◆【北京冠測精電儀器設備有限公司】產品系列--------熔體流動速率儀◆★◆
熔融指數儀報價,熔融指數測定儀,熔體流動速率實驗,熔體流動速率測定儀,熔融指數測試,融指測定儀,熔體流動速率的測定,
------------------------------------------------------------------------
一、 用途:
First, the use of:
RTSL-400B熔體流動速率儀是按GB/T3682-2000的試驗方法測定熱塑性高聚物在高溫下流動性能的儀器,用于聚乙烯、聚丙烯、聚甲醛、ABS 樹脂、聚碳酸酯、尼龍氟塑料等高聚物在高溫下熔體流動速率的測定。適用于工廠企業及科研單位的生產和研究之中。
Rtsl-400b melt flow rate instrument is according to GB / t3682-2000 test method for measurement of the thermal plastic polymer under high temperature flow properties of instrument, for polyethylene, polypropylene, poly formaldehyde, ABS resin, polycarbonate, nylon fluorine plastic, etc. polymer determination of the melt flow rate at high temperature. Suitable for the production and research of factory enterprises and scientific research units.
二、 主要技術參數:
Two, the main technical parameters:
1、 擠壓出料部分:
1, extrusion part:
出料口直徑:Φ2.095±0.005毫米
Outlet diameter: 2.095 mm in diameter and 0.005 mm
出料口長度:8.000±0.025毫米
Outlet length: 8 + 0.025 mm
裝料筒直徑:Φ9.550±0.025毫米
Charging cylinder diameter: 9.550 mm in diameter and 0.025 mm
裝料筒長度:152±0.1毫米
Cartridge length: 152 + / - 0.1 mm
活塞桿頭直徑:9.475±0.015毫米
Piston rod head diameter: 9.475 + 0.015 mm
活塞桿頭長度:6.350±0.100毫米
Piston rod head length: 6.350 + 0.100 mm
2、 標準試驗負荷(八級)
2, standard test load (level eight)
1級:0.325kg=(活塞桿+砝碼托盤+隔熱套+1號砝碼體)
Level 1: 0.325kg= (piston rod + weight tray + heat insulation sleeve +1 weight)
2級:1.200 kg=(0.325+2號0.875砝碼)
Level 2: 1.200 kg= (0.325+2 0.875 weight)
3級:2.160 kg=(0.325+3號1.835砝碼)
Level 3: 2.160 kg= (0.325+3 1.835 weight)
4級:3.800 kg=(0.325+4號3.475砝碼)
Level 4: 3.800 kg= (0.325+4 3.475 weight)
5級:5.000 kg=(0.325+5號4.675砝碼)
Level 5: 5 kg= (0.325+5 4.675 weight)
6級:10.000 kg=(0.325+5號4.675砝碼+6號5.000砝碼)
Level 6: 10 kg= (0.325+5 4.675 weight +6 5 weight)
7級:12.500 kg=(0.325+5號4.675砝碼+6號5.000+7號2.500砝碼)
Level 7: 12.500 kg= (0.325+5 No. 4.675 weight 5.000+7 number +6 2.500 weight)
8級:21.600 kg=(0.325+2號0.875+3號1.835+4號
Level 8: 21.600 0.875+3 (0.325+2 No. 1.835+4 No. kg=
3.475+5號4.675+6號5.000+7號2.500+8號2.915砝碼)
3.475+5 No. 4.675+6 No. 5.000+7 No. 2.500+8 No. 2.915 weight
試驗負荷相對誤差≤0.5%。
Test load relative error is less than 0.5%.
3、溫度范圍:室溫---450℃。
3, temperature range: room temperature ---450.
4、恒溫精度:±0.2℃
4, constant temperature accuracy: + 0.2
5、電源電壓:220V±10% 50Hz
5, power supply voltage: 220V + 10% 50Hz
6、工作環境條件:環境溫度10℃—40℃;環境相對濕度為30%—80%;周圍無腐蝕性介質,無較強空氣對流;周圍無震動、無較強的磁場干擾。
6, working environment conditions: ambient temperature 10 degrees Celsius, 40 degrees Celsius; environmental relative humidity is 80% - 30%; around the non corrosive medium, no strong air convection; around no vibration, no strong magnetic field interference.
7、儀器外形尺寸:250×350×510(長×寬×高)。
7, instrument appearance size: 250 x 350 x 510 (length * width * height).
三、儀器的安裝與使用:
1、 儀器的調整:
A:儀器拆箱后,按裝箱單及附圖一所注明的名稱、數量清點與檢查儀器是否完好,技術文件、附件是否齊全,待檢查無損、無誤后再將儀器擦干凈,放在較穩固的工作臺上。
B:把聯接口模擋板的推拉桿(附圖二 序號1)向爐體內推入,從料筒的上端口向下看去,可看到口模擋板已將料筒下端口徑擋住約三分之一。放入口模。并用裝料桿(附圖一 序號6)將其壓到與口模擋板接觸為止。
C:把水準儀支架(附圖一 序號1)從料筒的上端口插入料筒,以水準泡為準,調節底座下面的四個調節螺釘(附圖二 序號6),使料筒達到鉛垂狀態(注:意即水準儀上的氣泡處于正中位置)。隨后取下水準儀。
四、注意事項:
1、單相電源插座必須有接地線孔,并可靠接地。
2、液晶顯示器上若出現異常顯示時,應按復位鈕后,重新設定試驗溫度,并啟動工作。
3、正常工作中,若爐溫大于450℃,則軟件保護,中斷加熱,并發出報警。
4、異常現象發生,如不能控溫,不能顯示等,應關機,進行檢修